Cables for alarm and lock systems»
|
|
Cables are used for electric systems of railway signaling, centralization and locking, fire alarm and fire fighting automatics, for laying indoors, in dry trunks and tunnels, in pipelines and for underground laying in aggressive environment provided that there are no mechanical loads on the cable, at design voltage equal to 380 V of alternating current with 50 Hz frequency or equal to 700 V of direct current.
|
|
|
|
Communication cables, communication wires»
|
PRPPM, PRPPMt are designed for operation at voltage of up to 380 V and frequency of up to 10 kHz at subscribers' telephone lines and in distribution networks of wire broadcasting, as well as for underground laying, laying in telephone conduits, collectors, laying with wire shaft or with steel wire on building walls and on overhead line towers in areas not exposed to strong glaze-frosts and winds. TRP are used for users' wiring of telephone distribution circuits, both indoor and on external building walls.
|
|
|
|
Control cables»
|
|
These cables are used for fixed connection to electric gauges, devices, jumper boards of electric switching arrangements.
|
|
|
|
Suspension multi-core cables»
|
|
These cables are designed to be used in passenger and cargo elevators of public use at nominal direct voltage of up to 460 V or at alternating voltage of up to 440 V with 60 Hz frequency.
|
|
|
|
Installation multi-core shielded cables»
|
They are used for fixed inter-device installation of electric appliances operating at alternating voltage of up to 500 V with 400 Hz frequency or at 750 V of direct voltage. The climatic design of these cables may be UHL or T, the category of placement may be 2-5 according to GOST 15150.
|
|
|
|
Power cables»
|
|
Power cables are used for electric power supply and allocation in fixed installations and they are rated for nominal alternating voltage of 660 V with 50 Hz frequency.
|
|
|
|
|
|
High-frequency intercity cables»
|
High-frequency intercity cables are used for intercity communication cable lines of transmission systems К-60 for frequencies of up to 250 kHz. Cables provide distant power supply with voltage of up to 690 V of alternating current with 50 Hz frequency. Cables are made in UHL climatic configuration with the category of placement 5 according to GOST 15150.
|
|
|
|
High-frequency local cables»
|
The cables are used at interoffice and subscriber lines with data transmission systems with temporary channel splitting and pulse-code modulation with transmission speed amounting to 2048 kB/s at voltage of remote power supply of up to 500 V of direct current. Cables are manufactured in climatic configuration UHL, reinforced cables may be also manufactured in configuration TS, while filled cables are manufactured in configuration T, the category of placement is 1 as per GOST 15150.
|
|
|
|
High-frequency paired cable»
|
These cables are used for structured cabling communication systems as per international standard ISO/IEC11801, they are designed for fixed wiring inside buildings and construction and for operation at frequencies of up to 100 MHz (category 5) at working voltage of up to 145 V of alternating current. The climatic design is U, the categories of placement are 3, 4 as per GOST 15150.
|
|
|
|
Symmetrical office cable»
|
|
The cable is used for inter- and intra-frame installation of equipment of digital systems of signal transmission at 2.048 Mb/s speed.
|
|
|
|
Shielded microphone cable, wire, and cord»
|
|
They are used for separate units comprising microphone sets, for connection of microphones with amplifying devices, tape-recorders, as well as they are used as power circuits and for installation of microphone lines. Cables are manufactured in climatic configurations UHL and T with the categories of placement 3,4 as per GOST 15150.
|
|
|
|
|
|
High-voltage wire PVVp»
|
|
These wires are used for connection of devices of engine ignition systems of cars, tractors, motorcycles and other machines. Operating temperature ranges from minus 40°С to plus 70 °С for climate configurations U and T, and from minus 60 °С to plus 70°С for climate configuration HL. Wires are manufactured in climate configuration U, T with the category of placement 2 as per GOST 15150.
|
|
|
|
Card wires»
|
|
Card wires are designed to be used in television antennas operating at nominal direct voltage of up to 24V.
|
|
|
|
Winding wire for submersible motors»
|
|
The wires are used for winding of stators of submersible electric motors operating in waters of artesian wells for long time at voltage of up to 380 V, 660 V of alternating current with 40-60 Hz frequency.
|
|
|
|
|
|
Aircraft cables»
|
Aircraft cables are used for inter- and intra-equipment installation of electrical appliances and outputs of airborn equipment of aircraft engineering at voltage of up to 600V of alternating current with frequency of up to 2000 Hz or at direct voltage of up to 850V at temperatures from minus 60°С to plus 105°С. Wires are manufactured in climatic configuration V as per GOST V 20 39 404-81.
|
|
|
|
Household wires»
|
|
Household wires are used for fixed wiring in lighting circuits, for installation and connection of low-voltage devices for household purposes to alternating current mains with voltage of up to 250V and frequency of 50Hz, for installation of thermocouples, including for repair purposes.
|
|
|
|
High-voltage wires»
|
|
PMVT-3, PVMTg-3, PVMT-20, PVMTg-40, RMPVN are high-voltage hook-up television wires used for fixed installation of high-voltage circuits of television equipment to direct nominal voltage equal to 3, 20.40 and 30 kV.
|
|
|
|
Wires for alarm systems»
|
MK1 MK4 are designed for sensors and alarm systems used at operating voltage of up to 60 V of alternating current with frequency of up to 60 Hz at ambient temperature from minus 40 °С to plus 60 °С. PVVS wires are used for fire alarm systems operating at voltage of up to 60 V of alternating current with 50 Hz frequency at ambient temperature from minus 40 °С to plus 60 °С.
|
|
|
|
Wires for collectors»
|
Wires for collectors. Operating temperatures range from minus 60 °С to plus 230 °С. Wires are manufactured in climatic configuration V with the category of placement 2 subject to GOST 15150.
|
|
|
|
Reinforced wires and cords»
|
|
Wires and cords reinforced with fixed two-pin plugs (VP), and jumper-cord reinforced with fixed two-pin plug and set socket (AP) are designed to connect electric machines and appliances for household and analogous purposes to electric networks of alternating current of up to 10 A and nominal voltage of up to 250 V subject to GOST 28244-96.
|
|
|
|
Connection wires and cords»
|
Connection wires and cords are used for connection of mobile and fixed installations for household purposes, of electrical appliances, electric tools, machines and devices for household and similar use to electric mains with nominal alternating voltage of up to 300/500 V and 380/660 V. SHVP 2х0.35 is designed for connection of low-voltage devises for household purposes to mains with voltage of up to 250V of alternating current with 50Hz frequency.
|
|
|
|
Unified strip conductors»
|
|
They are used for inter- and intra-equipment installation of electrical devices with nominal voltage of up to 350 V of direct current and 250 V of alternating current with frequency of 50 Hz. Operation at frequencies of up to 10 MHz is allowable. In case of fixed installation, wires may be used at temperatures ranging from minus 40 °С to plus 60 °С;
|
|
|
|
Hook-up wires»
|
MNV are small-size low voltage wires for installation by wire-wrap method or by soldering designed for operation at operating alternating voltage of up to 100V and frequency of up to 10 kHz. NV, NVM, NVE, NVME are wires designed for to be used in circuits of electric devices of general industrial grade at nominal alternating voltage of 600 V and 1000 V with frequency of up to 5000 Hz and direct voltage of 840 V and 1400V respectively.
|
|
|
|
Hook-up wires MGSHV, MGSHVE, MGSHVEV»
|
|
The wires are used for flexible and fixed intra- and inter- equipment installation of electrical appliances and outputs of electric equipment at voltage of up to 380 V for wires with 0.08-0.14 mm cross-section and 1000 V for wires with 0.2-1.5 mm cross-section with frequency of up to 10000 Hz and direct voltage of up to 500V and 1500V respectively at temperatures from minus 50 °С to plus 70 °С.
|
|
|
|
Heat-resistant and small-size hook-up wires»
|
|
MPO, MPOE are heat-resistant wires for fixed inter- and intra-equipment installation of electrical appliances at voltage of up to 380 V of alternating current with frequency of up to 2000 Hz and at voltage of up to 160 V of alternating current with frequency of up to 4 MHz or at voltage of 550V of direct current at temperature ranging from minus 50 °С to plus 100 °С.
|
|
|
|
Heat-and-radiation resistant hook-up wires MPF»
|
|
These wires are used for fixed and flexible intra- and inter-equipment installation of electrical appliances and outputs of electric equipment(for electrical ignition of gas-stoves) at voltage of up to 500 V of alternating current with frequency of up to 1000 Hz and direct voltage of up to 750 V at operating temperature varying from minus 60°С to plus 155°С.
|
|
|
|
Heat-and-radiation resistant wires»
|
These wires are used for fixed and flexible intra- and inter-equipment wiring of electrical appliances and for outputs of electric equipment at voltage of up to 500 V of alternating current with frequency of up to 1000 Hz or at 750 V of direct current. Wires are made in the climatic configuration V subject to GOST V 20 39 404-81.
|
|
|
|
Heat-resistant cables»
|
|
Heat-resistant cables are used for heating of floors, grounds and walls in young stock housing (PUFUE 60), in domestic heating appliances (PUFL 120) at voltage of up to 380 V of alternating current with frequency of up to 60 Hz. The climatic design is U, the category of placement is 3 subject to GOST 15150.
|
|
|
|
Telephone wires»
|
PKSV is an office wire for non-permanent plugging in cross connections of telephone stations at direct voltage of up to 120 V. The climatic design is UHL with the categories of placement 4, 5 and Т with the categories of placement 2, 3, 4 subject to GOST 15150. PTPZH is a broadcasting wire for mounting of wire broadcasting networks. Types of climatic design include UHL and T, the category of placement is 3 subject to GOST 15150;
|
|
|
|
Installation wires»
|
|
Installation wires are used for electric installations in case of stationary laying in lighting and power mains, for installation of electrical equipment, devices, mechanisms and engineering tools at nominal voltage of up to 450 V (for mains with 450/750 V voltage) with frequency of up to 400 Hz, or at direct voltage of up to 1000 V.
|
|
|
|
Installation wires for submersible motors»
|
|
These wires are used for connection to electrical networks with 380 V and 660 V design voltage of alternating current with frequency of 50 Hz of submersible motors continuously operating in waters of artesian wells under the pressure of up to 70 kgf/cm2 at ambient temperatures varying from minus 40 °С to plus 80 °С.
|
|
|
|
Radio-frequency cables»
|
|
Radio-frequency cables are used for mounting of transmitting and receiving antennas in radio and television stations, in radio communication and radiolocation systems, in electronics, computer aids of television control systems of different radio-frequency equipment, for inter- and intra-equipment installation of radio technical devices.
|
|
|
|
Radio-frequency cables for household TV and video equipment»
|
|
They are used for production of reinforced connection cords for video equipment, of cable sets for TV-receivers, of television extension cords, as well as for antenna cables and for television wiring inside dwelling and utility facilities.
|
|
|
|
Polyvinylchloride plastic pipes»
|
They are used for protection and additional insulation of current-carrying elements of different electrical devices operating at voltage of 1000 V of direct and alternating current with frequency of up to 50 Hz. Pipes are used at temperatures from minus 40 °С to plus 70 °С.
|
|
|
|
Car lamp cord»
|
|
The cord is used for configuration of car service lamps with nominal direct voltage of up to 42 V. The type of climatic design is "U", the category of placement may be 1,2,3 subject to GOST 15150.
|
|
|
|
Telephone cords»
|
SHTL, SHTPL are used for connection of wall outlets with telephone receivers. Climatic design is "U" for SHTL and "UHL" for SHTPL, the category of placement is 3.1 subject to GOST 15150. SHGES is a connection shielded communication cord designed to provide electric connection of ultra small electro-acoustic capsules with devices.
|
|
|
|
|
|
|
|
|
|